Skip to content

Hull Inspection Regulations C.R.C., c. 1432

Section 25

Version
In force until June 27, 2021

This provision is no longer in the consolidation.

The history holds one version of this provision.

Text deletedText added

Colours

The two versions say the same words: the change is a coming into force or a change of form.

 At a quadrennial or quinquennial inspection of a ship over five years old but not over 10 years old, in addition to the requirements of section 24, the following requirements shall apply:

(a) additional ceiling in holds and coal bunkers shall be removed to enable the condition of the inner bottom plating, pillar feet and the bottom plating of bulkheads and tunnel sides to be examined; if considered necessary by the inspector, all of the ceiling shall be removed; removal of additional ceiling and of fastenings, at the discretion of the inspector, shall apply also in the case of wooden ships;

(b) in ships with a single bottom, one additional strake of the limber boards and ceiling all the way fore and aft on each side shall be removed;

(c) all tanks that are used exclusively for oil fuel or oil fuel and fresh water, and all cofferdams adjacent to such tanks, shall be thoroughly cleaned, gas-freed and examined internally, except that

(i) in the case of double bottom tanks used exclusively for oil fuel or oil fuel and fresh water, where the foremost such tank has been thoroughly cleaned, gas-freed, inspected internally and found satisfactory to the inspector, the cleaning, gas-freeing and internal examination of the other double bottom tanks used for such purpose shall not be necessary where, upon a general external examination, the inspector finds their condition to be satisfactory, and

(ii) in the case of tanks used exclusively for oil fuel or oil fuel and fresh water, other than double bottom and peak tanks, the cleaning, gas-freeing and internal examination of those tanks shall not be necessary where, upon external examination, the inspector finds their condition to be satisfactory;

(d) lubricating oil tanks need not be examined internally where, upon external examination, the inspector finds their condition to be satisfactory;

(e) plating in way of the side scuttles shall be exposed for examination.

History of the ActShow the text in English and French, side by side

Unofficial reproduction of the consolidated text published by the Department of Justice Canada, permitted by the Reproduction of Federal Law Order. Only the official text is authoritative.

Section 25 — Hull Inspection Regulations — Compare two versions — Agora